Skip To Main Content

Logo Image

Geneva County Schools

Logo Title

2025-2026 Samson Elementary School Re-cabling project

SAES Re-Cabling Project Q & A

Question: Is there a preference or specification for the type of fiber that is to be used to replace existing fiber cables?

Answer: Yes, OM3 12-strand fiber should be used with 6 strands terminated on each end of the cable.

 

 

Question: Is there a specification for the face plates used on boxes for network drops?

Answer: Yes. Blue face plates should be installed.

 

 

Question: Can the IDF in the upper elementary building be moved to the small hallway on the other side of the wall from its current location?

Answer: Yes, the IDF can be relocated from the closet indicated by the red arrow to the hallway indicated by the green arrow in the picture below.

Question: Can cable trays be used in the hallways to run cabling to classrooms in the Main Building/Lower Elementary?

Answer: Yes, cable trays SHOULD be used and the dimensions of the hallways are indicated in the picture below.